Pipe Friction Loss Calculator (Darcy-Weisbach / Crane TP-410)
Calculate total head loss in piping systems using the Darcy-Weisbach equation with Haaland friction factor and Crane TP-410 fitting equivalent lengths. Supports multiple pipe materials, diameters, and fitting types.
Darcy-Weisbach / Haaland · Crane TP-410 fittings
1. System Inputs
Water ≈ 1 cSt · Light oil ≈ 30 cSt · Heavy oil ≈ 200+ cSt
Fittings & Valves
Applied to pipe friction + fitting losses. Static head is not affected.
Spot-Check Flow Rates (m³/h)
Enter 4 points from lowest to highest to build your system curve
| Flow (m³/h) | Pipe Friction (m) | Fittings Loss (m) | Re | Flow Regime | System Head (m) |
|---|---|---|---|---|---|
| 25 | 1.61 | 0 | 2,881 | Transitional ⚠ Fitting loss accuracy reduced | 11.61 |
| 50 | 5.2 | 0 | 5,762 | Turbulent | 15.2 |
| 75 | 10.45 | 0 | 8,643 | Turbulent | 20.45 |
| 100 | 17.25 | 0 | 11,524 | Turbulent | 27.25 |
System Curve
- System Curve
Pipe friction: hf = f × (L/D) × V²/(2g) — where f is the Darcy friction factor from the S.E. Haaland explicit approximation (valid for all flow regimes). Fitting losses: hm = K × V²/(2g) where K = fT × (Le/D) — Crane TP-410 method; fT is the fully-turbulent friction factor (depends on pipe material roughness); Le/D ratios from Crane TP-410. For Re < 4,000, fitting loss accuracy is reduced as fT assumes fully turbulent flow.